Urban network water quality monitoring system utilizes advanced sensing technology and real-time data processing capabilities to monitor the water quality changes of urban drainage pipe networks around the clock....

1、Urban network water quality monitoring system Product Overview

Urban network water quality monitoring system utilizes advanced sensing technology and real-time data processing capabilities to monitor the water quality changes of urban drainage pipe networks around the clock.Urban network water quality monitoring systemX transmits data directly to a designated server via 4G, supporting the MQTT protocol for transparent transmission of JSON data.

Data in other formats is transmitted via 4G to our cloud platform.We provide an HTTP interface for other platforms to access data.

The built-in 8GB TF card allows data to be stored in the memory card.

The baud rate of each serial port can be modified via commands, and required sensor parameters can also be added, modified, and deleted via commands.


2、Urban network water quality monitoring system Features

1.Built-in 3.6V 152AH lithium battery, guaranteed for three years of continuous operation.

2.IP68 waterproof, no worries about pipe flooding.

3.Two 485 interfaces: one for device configuration and one for sensor reading.

4.Supports Modbus RTU sensor reading and data storage.

5.Serial port baud rate can be independently modified.

6.Sensor communication port supports up to 32 nodes.


3、Urban network water quality monitoring system Specifications

Operating Voltage: 3.6V Internal Lithium Battery

Dimensions: 204x82x162mm

Environmental: Temperature: -40-85°C, Humidity: 5%-95%

Communication Type: RS485

Communication Protocol: Modbus RTU

Communication Distance: 300 meters

Baud Rate: 1200-115200 bps, default 9600 8 N 1

Protection Level: 600W lightning surge protection per RS-485 line, ±15kV ESD protection


4、Urban network water quality monitoring system Sensor parameters

Serial numberSensor typeMeasurement rangeMeasurement principleMeasurement accuracyConfiguration
1Temperature0~50℃High-precision digital sensor±0.3℃
2Electrical conductivity0~5000uS/cm, 0~10000uS/cmContact method of electrode±1.5%
3pH0~14 (ph)Electrochemistry (salt bridge)±0.1PH
4Dissolved oxygen0~20mg/LFluorescence lifetime method±2%
5Ammonium nitrogen0-1000.00mg/L(default)
0-100.00mg/l/ (customizable)
Ion selective electrode method10% of the reading, ±0.5℃
6Turbidity0~40NTU (optional)Scattering light method±1%
7Cash on delivery0~500mg/LUV254 absorption method±5%