Seepage Monitoring

Seepage Monitoring

Model:FT-SL1
Brand:fengtu
Seepage Monitoring, which is composed of field detection equipment and remote monitoring equipment, is used to monitor seepage data in areas such as DAMS and slopes of reservoirs....

Seepage Monitoring mainly consists of on-site inspection equipment, remote monitoring equipment and other parts.

Seepage Monitoring, which is composed of field detection equipment and remote monitoring equipment, is used to monitor seepage data in areas such as DAMS and slopes of reservoirs.On-site inspection equipment: composed of water meter, triangular weir, etc., responsible for measuring the seepage data of the reservoir and monitoring the flow rate of the reservoir site.

Remote monitoring equipment: that is, a remote control monitoring terminal, responsible for collecting data information detected by the on-site detection equipment and transmitting the on-site information to the monitoring center through wireless transmission.

Introduction to Seepage Monitoring

The water meter uses magnetostrictive sensor as liquid level measurement, and has the characteristics of high resolution, good stability, reliable performance, fast response speed, linear measurement, never wear, and long working life. The water meter measures the water head on the weir, and then calculate the flow rate based on the empirical formula of the weir trough (triangular weir, trapezoid weir, rectangular weir, etc.).

Seepage Monitoring Structure and Principle

The water measuring weir meter consists of a magnetic rod, a float ball, a measuring circuit and a stainless steel casing. When the water level in the weir trough changes, it will cause the float to generate a liquid level difference. The upper machine uses the current liquid level to subtract the calibration base value to the actual weir water level, and then calculates the flow rate according to the weir trough type.

Seepage Monitoring Product Features

●High precision, high resolution

●Good stability and fast response

●Low temperature drift

●Standard MODBUS protocol, strong applicability

Seepage Monitoring Specifications and Parameters

Specifications and modelsCZL-300CZL-500CZL-700
Measurement range0~300mm0~500mm0~700mm
Sensitivity≤0.01mm
Power supply voltageDC12V
Output signalRS485
Communication protocolMODBUS-RTU
Protection levelIP67
Insulation resistor≥10MΩ
Housing material304 stainless steel
External dimensionsΦ89×500mmΦ89×700mmΦ89×900mm